MSD Ignition Ontstekingsmodule/-doos

123 resultaat

Ontstekingsmodule/-doos 30
3 Op voorraad
logo
Ontstekingskast Digital
MSD6425

Ontstekingskast Digital

* High Output w/530 Volts And 135Mj Of Spark Energy * Efficient components use less current to produce more power * Set An Rpm Limit w/Two Rotary Dials In 100 Rpm Increments * Built-in LED for syst ...Meer tonen

* High Output w/530 Volts And 135Mj Of Spark Energy

* Efficient components use less current to produce more power

* Set An Rpm Limit w/Two Rotary Dials In 100 Rpm Increments

* Built-in LED for system checks

* All wires exit through a locked; sealed connector

* Compatible w/4/6/8 Cylinder Engines

1 Op voorraad
logo
Ontstekingskast
MSD6560

Ontstekingskast

* MSDs Popular 6M-2 w/Built-In Rev-Limiter * Multiple sparks improve starting/throttle response/idle quality * Circuitry is potted for a weather-proof housing * Weathertight connectors protect wiri ...Meer tonen

* MSDs Popular 6M-2 w/Built-In Rev-Limiter

* Multiple sparks improve starting/throttle response/idle quality

* Circuitry is potted for a weather-proof housing

* Weathertight connectors protect wiring from water and chemicals

7 Op voorraad
logo
Ontstekingskast Digital
MSD6201

Ontstekingskast Digital

* Will not accept a rev limiter * High Output w/530 Volts And 135Mj Of Spark Energy * Efficient components use less current to produce more power * Built-in LED for system checks * All wires exit ...Meer tonen

* Will not accept a rev limiter

* High Output w/530 Volts And 135Mj Of Spark Energy

* Efficient components use less current to produce more power

* Built-in LED for system checks

* All wires exit through a locked; sealed connector

* Compatible w/4/6/8 Cylinder Engines

1 Op voorraad
logo
Ontstekingskast Digital
MSD6423

Ontstekingskast Digital

High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with ...Meer tonen

High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with less current draw)

High RPM operation and maximum output using the Blaster HVC, PN 8252 or HVC II, PN 8253

Powerful capacitive discharge of multiple sparks improves performance

Consistently high spark energy of 135mJ to 150mJ for every firing, from idle to redline RPM

Increase spark series duration lasts for 18 of crankshaft rotation

Easily installs on 4, 6, 8-cylinder engines with distributors

Operates on most 7 to 28 volt electrical systems

Connects to points, magnetic pickups, and Hall/Crank Input distributors

Bluetooth connectivity to Mobile app interface for settings and monitors

MSD CAN communication for easy connectivity to MSDView using a CAN MSD Hub and Power Grid USB or CAN-USB Bridge 89982 product

Fully protected against an open coil, shorted coil & open load

Compact design full MSD power

Quickens throttle response & improves starting

Tach Output

Launch, Burnout, and Step Retard activation inputs available. This ignition box has a built-in tri step RPM rev limit controlled by the mobile app

Mobile app available settings: Cylinder selection, Step retard value, Launch RPM value, Burnout RPM value, Max (Race) RPM Value, Start retard value

Programmable Step Retard: On Ramp time, Off Delay, Off Ramp Time, Engine RPM for activation

Programmable Start Retard: 0, 10, 20 degrees

Alerts and monitors available

High level of security connection from phone to Ignition box (encryption) including sequence in push button implementation

Maximum programmable retard of 30 degrees

1 Op voorraad
logo
Ontstekingskast Digital
MSD64233

Ontstekingskast Digital

High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with ...Meer tonen

High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with less current draw)

High RPM operation and maximum output using the Blaster HVC, PN 8252 or HVC II, PN 8253

Powerful capacitive discharge of multiple sparks improves performance

Consistently high spark energy of 135mJ to 150mJ for every firing, from idle to redline RPM

Increase spark series duration lasts for 18 of crankshaft rotation

Easily installs on 4, 6, 8-cylinder engines with distributors

Operates on most 7 to 28 volt electrical systems

Connects to points, magnetic pickups, and Hall/Crank Input distributors

Bluetooth connectivity to Mobile app interface for settings and monitors

MSD CAN communication for easy connectivity to MSDView using a CAN MSD Hub and Power Grid USB or CAN-USB Bridge 89982 product

Fully protected against an open coil, shorted coil & open load

Compact design full MSD power

Quickens throttle response & improves starting

Tach Output

Launch, Burnout, and Step Retard activation inputs available. This ignition box has a built-in tri step RPM rev limit controlled by the mobile app

Mobile app available settings: Cylinder selection, Step retard value, Launch RPM value, Burnout RPM value, Max (Race) RPM Value, Start retard value

Programmable Step Retard: On Ramp time, Off Delay, Off Ramp Time, Engine RPM for activation

Programmable Start Retard: 0, 10, 20 degrees

Alerts and monitors available

High level of security connection from phone to Ignition box (encryption) including sequence in push button implementation

Maximum programmable retard of 30 degrees

2 Op voorraad
logo
Ontstekingskast
MSD65233

Ontstekingskast

High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with ...Meer tonen

High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with less current draw)

High RPM operation and maximum output using the Blaster HVC, PN 8252 or HVC II, PN 8253

Powerful capacitive discharge of multiple sparks improves performance

Consistently high spark energy of 135mJ to 150mJ for every firing, from idle to redline RPM

Increase spark series duration lasts for 18 of crankshaft rotation

Easily installs on 4, 6, 8-cylinder engines with distributors

Operates on most 7 to 28 volt electrical systems

Connects to points, magnetic pickups, and Hall/Crank Input distributors

Bluetooth connectivity to Mobile app interface for settings and monitors

MSD CAN communication for easy connectivity to MSDView using a CAN MSD Hub and Power Grid USB or CAN-USB Bridge 89982 product

Straight USB port to easily connect to MSDView using a laptop

Fully protected against an open coil, shorted coil & open load

Compact design full MSD power

Quickens throttle response & improves starting

Tach Output

Launch, Burnout, and Step Retard activation inputs available. This ignition box has a built-in tri step RPM rev limit controlled by the mobile app

Mobile app available settings: Step retard value, Launch RPM value, Burnout RPM value, Max (Race) RPM Value

Programmable Step Retard: On Ramp time, Off Delay, Off Ramp Time, Engine RPM for activation

Programmable Start Retard through rotary switches: 0, 10, 20 degrees

Programmable cylinder selection through rotary switches: 4, 6, and 8 cylinders

Alerts and monitors available

High level of security connection from phone to Ignition box (encryption) including sequence in push button implementation

Maximum programmable retard of 35 degrees

Programmable timing curves in 2D Plots or 3D tables (RPM vs Timing vs MAP Pressure) - You can plot the 3D graph and edit a table 20x20 either from Mobile app (Phone) or from MSDView (laptop)

Programmable Launch Timing (Seconds vs degrees after launch wire activation)

MAP sensor interface up to 400 kPA (58 PSI / 4 Bars)

Capable to program cylinder selection and start retard without a computer or app for old school racers (like 6425 or 6428 box)

5 Op voorraad
logo
Ontstekingskast Digital
MSD5520

Ontstekingskast Digital

* Capacitive Discharge Technology * Multiple Sparks Improve Starting And Idle * Full Power Output At High RPM * Connects to points/amplifiers/magnetic pickup distributors * Adjustable rev limiter ...Meer tonen

* Capacitive Discharge Technology

* Multiple Sparks Improve Starting And Idle

* Full Power Output At High RPM

* Connects to points/amplifiers/magnetic pickup distributors

* Adjustable rev limiter for overrev protection

4 Op voorraad
logo
HEI MODULE - STREET FIRE
MSD5596

HEI MODULE - STREET FIRE

* Replace The OEM Ignition Module w/Street Fire * Module Replaces OEM GM HEI And Street Fire Dist. * Fits Street Fire Dist. PN[8362] And OEM * Perfect For Budget Minded Enthusiasts

* Replace The OEM Ignition Module w/Street Fire

* Module Replaces OEM GM HEI And Street Fire Dist.

* Fits Street Fire Dist. PN[8362] And OEM

* Perfect For Budget Minded Enthusiasts

1 Op voorraad
logo
Ontstekingskast
MSD6421

Ontstekingskast

* All new housing; same reliable digital circuitry and performance * Built-In 2-Step Rev Control Adjustable w/Rotary Dials * Higher Output w/Up To 135Mj Of Spark Energy * Accepts Hall-effect; point ...Meer tonen

* All new housing; same reliable digital circuitry and performance

* Built-In 2-Step Rev Control Adjustable w/Rotary Dials

* Higher Output w/Up To 135Mj Of Spark Energy

* Accepts Hall-effect; points and mag pickup triggers

* Managed by an efficient digital processor

3 Op voorraad
logo
Ontstekingskast
MSD6462

Ontstekingskast

* Multiple spark; capacitive discharge ignition control * Multiple Sparks For 20 deg. of Crankshaft Rotation * Retards ignition timing 1-3 deg per/lb. of boost (max. 15 deg.) * Dash mounted adjusta ...Meer tonen

* Multiple spark; capacitive discharge ignition control

* Multiple Sparks For 20 deg. of Crankshaft Rotation

* Retards ignition timing 1-3 deg per/lb. of boost (max. 15 deg.)

* Dash mounted adjustable control knob

* Supplied w/3000/6000/7000/8000 Amp Rpm Modules

* Supplied w/Rubber Shock Mounts

* Programmable for 4/6/8 cyl. by cutting red/blue wire loops

* Built-In Soft Touch Rev Control Is Adjustable w/Rpm Modules

* 110 Millijoules Per Spark Up To 15000 RPM

* 470 Primary Voltage Output To Coil

* Accepts breaker points/amplifier/magnetic pickup trigger inputs

* Works on 12-18 volt electrical system

1 Op voorraad
logo
Ontstekingskast
MSD6520

Ontstekingskast

* Switch between 2 rev limits * Single stage retard for nitrous and top end performance. * Start retard eases pressure on the starter; flywheel and engine. * Adj. magnetic pickup compensation for a ...Meer tonen

* Switch between 2 rev limits

* Single stage retard for nitrous and top end performance.

* Start retard eases pressure on the starter; flywheel and engine.

* Adj. magnetic pickup compensation for accurate trigger signals.

* LED warns of trigger signal problems or faulty charging system.

1 Op voorraad
logo
Ontstekingskast
MSD6530

Ontstekingskast

* Advanced features allow for use in street and racing applications * PC Programmable w/Easy-to-use Windows based Pro-Data +Software * Plot A Boost Timing Map w/0.1 Deg. Per Psi Accuracy * Programm ...Meer tonen

* Advanced features allow for use in street and racing applications

* PC Programmable w/Easy-to-use Windows based Pro-Data +Software

* Plot A Boost Timing Map w/0.1 Deg. Per Psi Accuracy

* Programmable 3-Step Rev Limiter (100 RPM increments)

* Step retard for nitrous applications plus a boost timing map

* Capacitive Discharge tech. for fast rise time/max. spark energy

2 Op voorraad
logo
RPM-chip 3000 Serien
MSD8743

RPM-chip 3000 Serien

* Five Modules Provided * 200 RPM Increments; Even * From 3000-3800 RPM

* Five Modules Provided

* 200 RPM Increments; Even

* From 3000-3800 RPM

2 Op voorraad
logo
RPM-chip 6000 Serien
MSD8746

RPM-chip 6000 Serien

* Five Modules Provided * 200 RPM Increments; Even * From 6000-6800 RPM

* Five Modules Provided

* 200 RPM Increments; Even

* From 6000-6800 RPM

2 Op voorraad
logo
Ontstekingsmodule
MSD83647

Ontstekingsmodule

* Easily installs to non-computer controlled (4-Pin) HEI housings * Built-in adjustable rev limiter can easily be set externally * Advanced dwell control for improved high rpm output * The Hottest ...Meer tonen

* Easily installs to non-computer controlled (4-Pin) HEI housings

* Built-in adjustable rev limiter can easily be set externally

* Advanced dwell control for improved high rpm output

* The Hottest HEI Module you buy-period!

* Produces an incredible 8.5 amps of juice

* Adjust The Rev Limiter w/o Removing The Cap

* Fits in stock HEI distributors

2 Op voorraad
logo
RPM-chip 4000 Serien
MSD87441

RPM-chip 4000 Serien

* Five Modules Provided * 200 RPM Increments; Odd * From 4100-4900 RPM

* Five Modules Provided

* 200 RPM Increments; Odd

* From 4100-4900 RPM

3 Op voorraad
logo
Launch Controll Module, Power Grid
MSD7751

Launch Controll Module, Power Grid

* Make Last Minute Changes * Change Shift Light And RPM Launch

* Make Last Minute Changes

* Change Shift Light And RPM Launch

1 Op voorraad
logo
ARC Module, Power Grid
MSD7761

ARC Module, Power Grid

* Plugs Into CAN-BUS Bridge * For Use w/Power Grid Controller * 4-Connector CAN-Bus Hub required

* Plugs Into CAN-BUS Bridge

* For Use w/Power Grid Controller

* 4-Connector CAN-Bus Hub required

2 Op voorraad
logo
Module Kit, 9000 Series
MSD8750

Module Kit, 9000 Series

* Five Modules Provided * 200 RPM Increments; Even * From 10000-10800 RPM

* Five Modules Provided

* 200 RPM Increments; Even

* From 10000-10800 RPM

5 Op voorraad
logo
Module Kit, 9000 Series
MSD8751

Module Kit, 9000 Series

* Five Modules Provided * 200 RPM Increments; Even * From 11000-11800 RPM

* Five Modules Provided

* 200 RPM Increments; Even

* From 11000-11800 RPM

2 Op voorraad
logo
Adjustable RPM Module
MSD8677

Adjustable RPM Module

* Simple Adjustable Low RPM Module * Dial In Any RPM Range Between 1K And 3K * Change RPM By Turning A Potentiometer * Great w/Auto Tranny Using MSD 2 Step Mod Selector

* Simple Adjustable Low RPM Module

* Dial In Any RPM Range Between 1K And 3K

* Change RPM By Turning A Potentiometer

* Great w/Auto Tranny Using MSD 2 Step Mod Selector

1 Op voorraad
logo
RPM-chip 8000 Serien
MSD8748

RPM-chip 8000 Serien

* Five Modules Provided * 200 RPM Increments; Even * From 8000-8800 RPM

* Five Modules Provided

* 200 RPM Increments; Even

* From 8000-8800 RPM

2 Op voorraad
logo
RPM-chip 3000 Serien
MSD87431

RPM-chip 3000 Serien

* Five Modules Provided * 200 RPM Increments; Odd * From 3100-3900 RPM

* Five Modules Provided

* 200 RPM Increments; Odd

* From 3100-3900 RPM

Levering
logo
Ontstekingskast
MSD6523

Ontstekingskast

High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with ...Meer tonen

High conversion efficiency ensures minimal heat generation and maximum spark energy output with less current draw from the battery - (Highly efficient Ignition, minimum heat and max spark energy with less current draw)

High RPM operation and maximum output using the Blaster HVC, PN 8252 or HVC II, PN 8253

Powerful capacitive discharge of multiple sparks improves performance

Consistently high spark energy of 135mJ to 150mJ for every firing, from idle to redline RPM

Increase spark series duration lasts for 18 of crankshaft rotation

Easily installs on 4, 6, 8-cylinder engines with distributors

Operates on most 7 to 28 volt electrical systems

Connects to points, magnetic pickups, and Hall/Crank Input distributors

Bluetooth connectivity to Mobile app interface for settings and monitors

MSD CAN communication for easy connectivity to MSDView using a CAN MSD Hub and Power Grid USB or CAN-USB Bridge 89982 product

Straight USB port to easily connect to MSDView using a laptop

Fully protected against an open coil, shorted coil & open load

Compact design full MSD power

Quickens throttle response & improves starting

Tach Output

Launch, Burnout, and Step Retard activation inputs available. This ignition box has a built-in tri step RPM rev limit controlled by the mobile app

Mobile app available settings: Step retard value, Launch RPM value, Burnout RPM value, Max (Race) RPM Value

Programmable Step Retard: On Ramp time, Off Delay, Off Ramp Time, Engine RPM for activation

Programmable Start Retard through rotary switches: 0, 10, 20 degrees

Programmable cylinder selection through rotary switches: 4, 6, and 8 cylinders

Alerts and monitors available

High level of security connection from phone to Ignition box (encryption) including sequence in push button implementation

Maximum programmable retard of 35 degrees

Programmable timing curves in 2D Plots or 3D tables (RPM vs Timing vs MAP Pressure) - You can plot the 3D graph and edit a table 20x20 either from Mobile app (Phone) or from MSDView (laptop)

Programmable Launch Timing (Seconds vs degrees after launch wire activation)

MAP sensor interface up to 400 kPA (58 PSI / 4 Bars)

Capable to program cylinder selection and start retard without a computer or app for old school racers (like 6425 or 6428 box)

Levering
logo
Atomic Trans Controller, Handheld Only
MSD2762

Atomic Trans Controller, Handheld Only

* Replacement Handheld For The Transmission * Control Module * Easy To View Parameters * Lcd Contrast Adjustment * Backlight Level Adjustment

* Replacement Handheld For The Transmission

* Control Module

* Easy To View Parameters

* Lcd Contrast Adjustment

* Backlight Level Adjustment

Levering
logo
Ontstekingskast
MSD4224

Ontstekingskast

* Adjustable Timing Controls * Adjustable Individual Cylinder Timing * Adjustable Timed Launch Retard * Adjustable Retards * Adjustable Boost Retard Curve * Adjustable Shift Programs

* Adjustable Timing Controls

* Adjustable Individual Cylinder Timing

* Adjustable Timed Launch Retard

* Adjustable Retards

* Adjustable Boost Retard Curve

* Adjustable Shift Programs

Levering
logo
Ontstekingskast
MSD4244

Ontstekingskast

* Direct Plug In * Instant MPH Increases * 10 Timing/Fuel Maps * Laptop Programmable * Built In Chaperone Setting

* Direct Plug In

* Instant MPH Increases

* 10 Timing/Fuel Maps

* Laptop Programmable

* Built In Chaperone Setting

Hits/pagina